Wall ties are connections used in cavity wall construction. Their condition and distribution can become relevant when a survey identifies concerns about masonry restraint.

Different buildings need different assessment

Tie type and arrangement depend on the construction. Original walls and extensions may differ. The age of a property or the presence of metal ties does not automatically establish a need for replacement.

Inspections are sampled

A specialist may locate ties and inspect selected positions through drilled borescope holes or openings. Insulation can restrict the view, and selected bricks may need removal. The report should state what could and could not be assessed.

Recommendations need evidence

Some findings may justify further investigation, monitoring or remedial ties. The specification should suit the masonry, chosen system and building. Keep the report and any completion records, rather than treating a general description of wall ties as an assessment of your property.

Discuss your property

For wall tie survey, send your postcode, relevant photographs and any existing survey findings. The inspection scope and fee are agreed before booking. Call 0333 220 2463 or contact CavClear. Read more about our wall tie survey services.